Hof testing services flyer EN - Flipbook - Seite 2
Our portfolio of test possibilities includes
Climate Chamber 1 and 2
Climate Chamber 3 and 4
Characteristics
Two identical climate chambers with sliding doors
Two identical climate chambers with sliding doors
Size (WxDxH)
5.300 mm x 6.000 mm x 4.400 mm
11.300 mm x 5.500 mm x 3.100 mm
Possible temperature range
-30°C to +60°C
+18°C to +40°C
Standard ambient humidity
Rel. Humidity range
40 - 80%
Possibility for maximum humidification ~85%
Examples of testing possibilities
+ Temperature and humidity measurement under
climatic conditions
+ Determination of cooling performance
+ Performance measurement on air-to-air
refrigeration units
+ Performance measurement on brine refrigeration
units
+ Humidified defrosting on refrigeration units
+ Energy measurement e.g. on refrigeration units
+ Temperature and humidity measurement under
climatic conditions
+ Determination of cooling performance
+ Testing of components for condensation
precipitation at high humidity levels
+ Energy measurement e.g. on cold rooms with
refrigeration units or refrigerated cabinets
Application standards
DIN EN 17432
DIN EN ISO 23953-2
Specific test possibilites
Due to our specific measurement equipment we have the opportunity to
implement a wide range of other tests. Our equipment allows individual
measurement of:
+ temperature (°C)
+ pressure (bar / Pa)
+ humidity (%)
+ velocity (m/s)
+ acceleration (m²/s)
+ force (N)
+ light intensity (Lux)
+ and more
SOME EXAMPLES OF FURTHER POSSIBILTIES:
+ Rollover test stand for floors with different roller spacings and load classes
(Room temperatures from -25°C to ~20°C, completely automatic)
+ Throw distance test stand for measuring the throw ranges of air-to-air
refrigeration units
viessmann-cool.com
EN 11/2023