Refrigeration units from Viessmann - Catalog - Page 19
PROGRAMME AND PERFORMANCE OVERVIEW
WSC2 - Packaged Meat
Model
WSC2 900 PM
WSC2 1300 PM
WSC2 1700 PM
Cooling capacity [W] 1
900
1300
1700 / 1400
Room volume up to [m³] 2
15
20
25
Cold room temperature adjustment range [°C]
+2 to +20
+2 to +20
+2 to +20
Allowed ambient
temperature [°C] ³
- 15 to +43
- 15 to +43
- 15 to +43
Refrigerant / GWP ⁴
R513A / 573
R513A / 573
R513A / 573
32/32
33/33
34 / 34
230 / 1 / 50
230 / 1 / 50
230 / 1 / 50
Electrical
Electrical
Electrical
Dimensions condensing unit
HxWxD [mm]
837 x 942 x 654
837 x 942 x 654
600 x 900 x 350
Dimensions evaporator
HxWxD [mm]
176 x 928 x 515
176 x 928 x 515
455 x 752 x 430
Sound pressure [dB(A)] 5
Voltage / Phases /
Frequency [V/-/Hz]
Defrosting type
WSC2 - Packaged Meat
Model
WSC2 2100 PM
WSC2 2600 PM
WSC2 3700 PM
WSC2 5100 PM
WSC2 6400 PM
2100
2600
3700
5100
6400
35
45
70
105
140
Cold room temperature adjustment range [°C]
+2 to +20
+2 to +20
+2 to +20
+2 to +20
+2 to +20
Allowed ambient
temperature [°C] ³
- 15 to +43
- 15 to +43
- 15 to +43
- 15 to +43
- 15 to +43
Refrigerant / GWP ⁴
R513A / 573
R513A / 573
R513A / 573
R513A / 573
R513A / 573
34 / 34
39 / 36
40 / 37
40 / 37
41 / 38
230 / 1 / 50
400 / 3 / 50
400 / 3 / 50
400 / 3 / 50
400 / 3 / 50
Electrical
Electrical
Electrical
Electrical
Electrical
Dimensions condensing unit
HxWxD [mm]
600 x 900 x 350
840 x 1030 x 425
840 x 1030 x 425
840 x 1030 x 425
1245 x 1030 x 425
Dimensions evaporator
HxWxD [mm]
455 x 752 x 430
455 x 752 x 430
455 x 1212 x 430
455 x 1212 x 430
455 x 1672 x 430
Cooling capacity [W] 1
Room volume up to [m³] 2
Sound pressure [dB(A)] 5
Voltage / Phases /
Frequency [V/-/Hz]
Defrosting type
¹ Condensing unit, Evaporation temperature t₀ -7°C; ambient temperature + 32°C; evaporator superheat 10K; influences of installation location and other refrigeration circuit
components must be considered independently
² Basis of calculation for room size: Room temperature +2°C, Ambient temperature +25°C
Heat extraction from goods 15K, operating time 16 h/day, goods handling 1/7 per day, inspection and lighting 0.5 h / day
³ Max. Compressor inlet superheat 20K
⁴ Based on AR6 / IPCC
⁵ Condensing unit, A-weighted equivalent sound pressure level at a distance of 10m