PROGRAMME AND PERFORMANCE OVERVIEW
WSF2 - Frozen Goods
Model
WSF2 1000
WSF2 1400
WSF2 1800
900
1300
1800
10
12
15
-25 to -5
-25 to -5
-25 to -5
- 15 to +43
- 15 to +43
- 15 to +43
R449A/1397
R449A/1397
R449A/1397
39 / 36
40 / 37
39 / 36
400 / 3 / 50
400 / 3 / 50
400 / 3 / 50
Electrical
Electrical
Electrical
Dimensions condensing unit
HxWxD [mm]
837 x 942 x 654
842 x 1174 x 575
840 x 1029 x 424
Dimensions evaporator
HxWxD [mm]
176 x 928 x 515
176 x 928 x 515
455 x 752 x 430
WSF2 2600
WSF2 3900
WSF2 4500
2600
3900
4500
30
50
60
-25 to -5
-25 to -5
-25 to -5
- 15 to +43
- 15 to +43
- 15 to +43
R449A/1945
R449A/1945
R449A/1945
40 / 37
40 / 37
41 / 38
400 / 3 / 50
400 / 3 / 50
400 / 3 / 50
Electrical
Electrical
Electrical
840 x 1030 x 425
840 x 1030 x 425
1245 x 1030 x 425
455 x 752 x 430
455 x 1212 x 430
455 x 1212 x 430
Cooling capacity [W] 1
Room volume up to [m³] 2
Cold room temperature
adjustment range [°C]
Allowed ambient
temperature [°C] ³
Refrigerant / GWP ⁴
Sound pressure [dB(A)] 5
Voltage / Phases /
Frequency [V/-/Hz]
Defrosting type
WSF2 - Frozen Goods
Model
Cooling capacity [W] 1
Room volume up to [m³] 2
Cold room temperature
adjustment range [°C]
Allowed ambient
temperature [°C] ³
Refrigerant / GWP ⁴
Sound pressure [dB(A)] 5
Voltage / Phases /
Frequency [V/-/Hz]
Defrosting type
Dimensions condensing unit
HxWxD [mm]
Dimensions evaporator
HxWxD [mm]
¹ Condensing unit; evaporation temperature t₀ -30°C, ambient temperature + 32°C; evaporator superheat 10K; influences of installation location and other refrigeration circuit
components must be considered independently
² Basis of calculation for room size: room temperature -21°C, ambient temperature +25°C
Heat extraction from goods 15K, operating time 16 h/day, goods handling 1/7 per day, inspection and lighting 0.5 h / day
³ Max. compressor inlet superheat 20K
⁴ Based on AR6 / IPCC
⁵ Condensing unit, A-weighted equivalent sound pressure level at a distance of 10m