Refrigeration units from Viessmann - Catalog - Page 10
PROGRAMME AND PERFORMANCE OVERVIEW
Tecto RF WSC2 - Packaged Food
Model
WSC2 1800 PF
WSC2 2200 PF
WSC2 2800 PF
WSC2 4100 PF
WSC2 5500 PF
1800 / 1600
2200 / 1900
2800 / 2300
4100 / 3400
5500 / 4600
30
40
55
90
130
+5 to +20
+5 to +20
+5 to +20
+5 to +20
+5 to +20
- 15 to +43
- 15 to +43
- 15 to +43
- 15 to +43
- 15 to +43
R513A / 573
R513A / 573
R513A / 573
R513A / 573
R513A / 573
34 / 34
34 / 34
39 / 36
40 / 37
40 / 37
230 / 1 / 50
230 / 1 / 50
400 / 3 / 50
400 / 3 / 50
400 / 3 / 50
Circulating air
Circulating air
Circulating air
Circulating air
Circulating air
Dimensions condensing unit
HxWxD [mm]
600 x 900 x 350
600 x 900 x 350
840 x 1030 x 425
840 x 1030 x 425
840 x 1030 x 425
Dimensions evaporator
HxWxD [mm]
455 x 752 x 430
455 x 752 x 430
455 x 752 x 430
455 x 1212 x 430
455 x 1212 x 430
Cooling capacity [W] 1
Room volume up to [m³] ²
Cold room temperature
adjustment range [°C]
Allowed ambient
temperature [°C] ³
Refrigerant / GWP ⁴
Sound pressure [dB(A)] 5
Voltage / Phases /
Frequency [V/-/Hz]
Defrosting type
Tecto RF WSC2 - Packaged Meat
Model
WSC2 1700 PM
WSC2 2100 PM
WSC2 2600 PM
WSC2 3700 PM
WSC2 5100 PM
WSC2 6400 PM
1700 / 1400
2100 / 1800
2600 / 2100
3700 / 3100
5100 / 4300
6400 / 5400
25
35
45
70
105
140
+2 to +20
+2 to +20
+2 to +20
+2 to +20
+2 to +20
+2 to +20
- 15 to +43
- 15 to +43
- 15 to +43
- 15 to +43
- 15 to +43
- 15 to +43
R513A / 573
R513A / 573
R513A / 573
R513A / 573
R513A / 573
R513A / 573
34 / 34
34 / 34
39 / 36
40 / 37
40 / 37
41 / 38
230 / 1 / 50
230 / 1 / 50
400 / 3 / 50
400 / 3 / 50
400 / 3 / 50
400 / 3 / 50
Electrical
Electrical
Electrical
Electrical
Electrical
Electrical
Dimensions condensing unit
HxWxD [mm]
600 x 900 x 350
600 x 900 x 350
840 x 1030 x 425
840 x 1030 x 425
840 x 1030 x 425 1245 x 1030 x 425
Dimensions evaporator
HxWxD [mm]
455 x 752 x 430
455 x 752 x 430
455 x 752 x 430
455 x 1212 x 430
455 x 1212 x 430
Cooling capacity [W] ⁶
Room volume up to [m³] ⁷
Cold room temperature
adjustment range [°C]
Allowed ambient
temperature [°C] ³
Refrigerant / GWP ⁴
Sound pressure [dB(A)] 5
Voltage / Phases /
Frequency [V/-/Hz]
Defrosting type
1
2
455 x 1672 x 430
Condensing unit; Evaporation temperature t₀ -5°C, ambient temperature + 32°C / 43°C; Evaporator Superheat 10K; influences of installation location and other refrigeration
circuit components must be considered independently
Basis of calculation for room size: Room temperature +5°C, Ambient temperature +25°C, heat extraction from goods 15 K, operating time 16 h/day,
goods handling 1/7 per day, inspection and lighting 0.5 h / day
3
max. Compressor inlet superheat 20K
4
based on AR5 / IPCC
5
Condensing unit, A-weighted equivalent sound pressure level at 10m distance
6
Condensing unit; Evaporation temperature t₀ -7°C, ambient temperature + 32°C / 43°C; Evaporator Superheat 10K; influences of installation location and other refrigeration
circuit components must be considered independently
7
Basis of calculation for room size: Room temperature +2°C, Ambient temperature +25°C, heat extraction from goods 15 K, operating time 16 h/day, goods handling 1/7 per
day, inspection and lighting 0.5 h / day